HM10 Humidty Analyzer | HighSeek
Reliable Online Moisture Measurement for Industrial Flue Gas Monitoring
The HM10 Industrial Flue Gas Humidity Monitor is designed for continuous online measurement of water vapor content in industrial flue gas. It is widely used in thermal power plants, chemical processing facilities, steel mills, and other industrial applications, particularly for monitoring flue gas humidity before and after desulfurization processes.
Based on advanced capacitive-resistive humidity sensing technology, the HM10 provides real-time measurement of flue gas moisture with high accuracy and reliable long-term performance.
Featuring an integrated rack-mounted design, automatic temperature compensation, and a specially engineered measurement chamber, the HM10 effectively minimizes the influence of ambient temperature variations, dust, and liquid water on measurement stability.
Its two-stage filtration system helps prevent dust and acidic liquid contamination, while the corrosion-resistant 316F stainless steel sensor probe ensures reliable operation in challenging industrial environments.
Equipped with an LCD touchscreen and multiple signal output interfaces, including 4-20 mA and RS485, the HM10 offers convenient operation, flexible system integration, and low maintenance requirements.
Key Features and Advantages
1. Advanced Capacitive-Resistive Measurement Technology
Utilizes capacitive-resistive sensing technology for continuous measurement of water vapor content in industrial flue gas.
Provides real-time humidity monitoring with a measurement range of 0-40% vol, making it suitable for various industrial exhaust gas applications.
2. High-Precision Automatic Temperature Compensation
Features an automatic temperature compensation function to minimize the influence of ambient temperature fluctuations on measurement results.
Helps maintain stable and reliable humidity measurements under varying operating conditions.
3. Specially Designed Measurement Chamber
Features a dedicated test chamber designed to reduce the impact of dust and liquid water on the humidity-sensitive element.
The optimized chamber structure helps improve measurement stability and extend sensor service life in demanding flue gas environments.
4. Two-Stage Filtration for Dust and Acidic Liquid Protection
Incorporates a two-stage filtration structure to effectively reduce dust particles and acidic liquid contamination entering the measurement chamber.
Helps protect the internal sensing element, minimize contamination-related failures, and improve long-term operational reliability.
5. Corrosion-Resistant 316F Stainless Steel Probe
The internal sensor probe is manufactured from 316F stainless steel, offering good corrosion resistance and mechanical durability for industrial flue gas applications.
Designed to withstand challenging operating conditions commonly encountered in desulfurization and industrial exhaust gas treatment systems.
6. Integrated Rack-Mounted Design
Features a compact integrated structure for convenient installation and electrical connection.
The integrated design helps reduce the influence of external interference on measurement signals while simplifying system configuration and maintenance.
7. LCD Touchscreen and User-Friendly Operation
Equipped with an LCD touchscreen for convenient parameter configuration, real-time measurement display, and instrument operation.
The intuitive interface simplifies routine inspection and maintenance.
8. Flexible Analog and Digital Signal Outputs
Provides both 4-20 mA analog output and RS485 digital communication, allowing users to select the preferred signal interface according to their control system requirements.
Designed for integration with CEMS platforms, PLCs, DCS systems, and industrial environmental monitoring equipment.
9. Reliable Long-Term Operation and Low Maintenance
Designed for continuous industrial operation with stable measurement performance and a humidity-sensitive capacitor service life of approximately three years under specified operating conditions.
The integrated structure and protective filtration design help reduce routine maintenance requirements and operating costs.
Technical Specifications
Measurement Performance
| Parameter | Specification |
|---|---|
| Measurement Principle | Capacitive-Resistive Method |
| Measurement Range | 0-40% vol (Absolute Humidity) |
| Measurement Accuracy | ±1.5% F.S. |
| Response Time (T90) | ≤120 seconds |
| Temperature Compensation | Automatic |
| Humidity-Sensitive Capacitor Service Life | Approximately 3 years |
Operating Conditions
| Parameter | Specification |
|---|---|
| Maximum Flue Gas Temperature | Less than 125 °C |
| Ambient Operating Temperature | 0 to +50 °C |
| Applicable Medium | Industrial Flue Gas |
| Filtration System | Two-Stage Filtration |
| Sensor Probe Material | 316F Stainless Steel |
Electrical and Communication Interfaces
| Parameter | Specification |
|---|---|
| Analog Output | 1 × 4-20 mA |
| Digital Communication | 1 × RS485 |
| Power Supply | 220 VAC, 50 Hz |
| Display | LCD Touchscreen |
General Specifications
| Parameter | Specification |
|---|---|
| Installation Type | Rack-Mounted |
| Weight | Approximately 4 kg |
Typical Applications
- Flue Gas Humidity Monitoring Before and After Desulfurization
- Thermal Power Plants and Coal-Fired Boilers
- Wet Flue Gas Desulfurization (WFGD) Systems
- Chemical and Petrochemical Processing Plants
- Iron and Steel Manufacturing
- Industrial Exhaust Gas Treatment Systems
- Continuous Emission Monitoring Systems (CEMS)
- Environmental Monitoring and Industrial Process Control
Why Choose the HM10 Flue Gas Humidity Monitor?
Accurate flue gas moisture measurement is essential for reliable environmental monitoring, emission data evaluation, and industrial process optimization.
The HM10 combines capacitive-resistive sensing technology, automatic temperature compensation, a protective two-stage filtration system, and a corrosion-resistant sensor probe to provide dependable humidity monitoring in demanding industrial environments.
Its compact rack-mounted design, intuitive touchscreen interface, and flexible signal outputs make it easy to integrate into existing CEMS installations and industrial control systems.
Whether monitoring moisture levels in desulfurization processes or supporting continuous industrial emission monitoring, the HM10 provides a practical and reliable solution for online flue gas humidity measurement.
Contact our technical team for product specifications, integration support, and customized flue gas humidity monitoring solutions.