CX200 Continuous Emission Monitoring System CEMS | HighSeek

Designed for demanding industrial environments, the CX200 integrates gas sampling, sample conditioning, multi-component gas analysis, particulate matter monitoring, flue gas parameter measurement, and data acquisition into a comprehensive monitoring platform.

Category: Tag: Brand:

CX200 Continuous Emission Monitoring System CEMS | HighSeek

Integrated Continuous Emission Monitoring for Industrial Exhaust Gas

The CX200 Continuous Emission Monitoring System (CEMS) is an integrated environmental monitoring solution designed for real-time, continuous measurement of air pollutants and flue gas parameters from industrial emission sources.

Designed for demanding industrial environments, the CX200 integrates gas sampling, sample conditioning, multi-component gas analysis, particulate matter monitoring, flue gas parameter measurement, and data acquisition into a comprehensive monitoring platform.

The system continuously monitors key emission parameters, including sulfur dioxide (SO2), nitric oxide (NO), nitrogen dioxide (NO2), nitrogen oxides (NOx), oxygen (O2), carbon monoxide (CO), carbon dioxide (CO2), particulate matter concentration, flue gas temperature, pressure, velocity, and humidity.

Featuring flexible cold-dry, hot-wet, and cold-hot sampling configurations, the CX200 can be customized to meet different application requirements and flue gas characteristics. Its integrated industrial computer processes, displays, and stores measurement data, while network communication enables data transmission to remote monitoring platforms and environmental regulatory authorities.

With intelligent system integration, reliable sample conditioning, and convenient maintenance functions, the CX200 provides an effective solution for industrial emission monitoring, environmental compliance management, and continuous process supervision.

Key Features and Advantages

1. Integrated CEMS Solution

Combines gas sampling, sample pretreatment, gas analysis, particulate matter monitoring, flue gas parameter measurement, and data acquisition in one integrated system.

Supports multiple monitoring parameters to provide comprehensive information on industrial emission conditions.

2. Flexible Sampling and Conditioning Technologies

Supports cold-dry, hot-wet, and cold-hot sampling configurations to accommodate different flue gas compositions, moisture levels, and operating conditions.

The system configuration can be selected according to application requirements to help maintain sample integrity and measurement reliability.

3. Direct NO2 Measurement for Improved NOx Accuracy

Supports direct NO2 measurement rather than relying solely on NOx conversion. This helps minimize conversion-related measurement errors and improves the reliability of nitrogen oxide monitoring.

4. Advanced Dust Filtration and Automatic Backflushing

Adopts multi-stage dust filtration technology combined with scheduled automatic backflushing to reduce dust accumulation and prevent clogging in sampling filters, pipelines, and analyzer measurement units.

This design improves system reliability and helps maintain continuous operation under high-dust and harsh industrial conditions.

5. Intelligent Industrial Control and User Interface

Equipped with an industrial computer for real-time data display, processing, and storage. A dedicated touchscreen interface provides convenient visualization of gas flow and system operating conditions.

The user-friendly interface simplifies system operation, routine inspection, and maintenance.

6. Remote Data Transmission and Environmental Monitoring Integration

Supports network communication for transmitting monitoring data to remote computers and higher-level environmental monitoring platforms.

Facilitates centralized data management, remote supervision, and integration with industrial environmental monitoring networks.

7. Easy Maintenance and System Integration

Designed with an integrated system architecture and accessible maintenance configuration to simplify routine inspection and servicing.

Its flexible configuration supports integration with different industrial emission monitoring applications.

8. Customized Monitoring Solutions

Provides customizable system configurations based on specific emission sources, gas components, measurement ranges, sampling conditions, and customer requirements.

Technical Specifications

Gas Measurement Parameters

Gas Component Measurement Range
SO2 0-100 / 0-5,000 ppm (Customizable)
NO 0-100 / 0-5,000 ppm (Customizable)
NO2 0-100 / 0-5,000 ppm (Customizable)
NOx 0-100 / 0-5,000 ppm (Customizable)
O2 0-25% vol (Customizable)
CO 0-3,000 ppm (Customizable)
CO2 0-20% vol (Customizable)

Performance Specifications

Parameter Specification
Repeatability Less than 2%
Zero Drift Less than ±2% F.S./week
Span Drift Less than ±2% F.S./week
Response Time (T90) 120 seconds
Operating Temperature -10 to +50 °C

System Configuration

Parameter Specification
Sampling Methods Cold-Dry / Hot-Wet / Cold-Hot
Monitoring Parameters Gas Concentrations, Particulate Matter, Flue Gas Temperature, Pressure, Velocity, and Humidity
Control System Industrial Computer
User Interface Touchscreen Display
Data Processing Real-Time Data Processing and Storage
Data Transmission Network Communication
System Configuration Customizable

General Specifications

Parameter Specification
System Dimensions (W × D × H) 800 × 600 × 2,000 mm
Power Supply 220 VAC

Typical Applications

  • Coal-Fired Power Plants
  • Industrial Boilers and Heating Systems
  • Waste Incineration and Waste-to-Energy Plants
  • Cement and Building Materials Industries
  • Iron and Steel Manufacturing
  • Chemical and Petrochemical Industries
  • Industrial Furnaces and Kilns
  • Environmental Protection and Emission Monitoring Projects
  • Industrial Exhaust Gas Treatment Systems

Why Choose the CX200 CEMS?

The CX200 provides an integrated approach to continuous industrial emission monitoring by combining gas analysis, particulate matter measurement, flue gas parameter monitoring, and intelligent data management.

Its flexible sampling configurations, advanced dust filtration, automatic backflushing, and integrated control platform make it suitable for demanding industrial operating environments.

Whether used in power generation, manufacturing, waste treatment, or industrial exhaust gas management, the CX200 helps operators obtain reliable emission data, improve environmental monitoring efficiency, and maintain better control over industrial discharge processes.

Looking for a customized CEMS solution? Contact our technical team to discuss your emission monitoring requirements, sampling configuration, gas measurement ranges, and system integration needs.

 

Can’t find the product you need?

Contact our experts now for a professional consultation and personalized model selection.
Scroll to Top